Trust
Mark R. Mandel, MD

Mark R. Mandel, MD has been selected by hundreds of eye doctors and other physicians to perform LASIK, corneal transplant, and cataract surgery on themselves, their families, and their office staff.

Read More >>
Experience
Mark R. Mandel, MD

As a sub-specialist Dr. Mandel has performed over 60,000 LASIK procedures and 20,000 cataract/IOL procedures. He has been serving Bay Area patients since 1983.

Read More >>
Innovation
Mark R. Mandel, MD

We are proud to offer state of the art technology for measuring the eye and performing the latest in advanced surgical techniques. Striving to achieve the best possible outcomes.

Read More >>
Recognition
Mark R. Mandel, MD

Graduate of Oxford University, UCLA School of Medicine, Fellowship trained cornea transplant and refractive specialist. Chosen by more surgeons to perform surgery on themselves and their families.

Read More >>
877-210-2020


Category Archives: Presbyopia Correction

Kamra Inlay for Presbyopia

As you know, the FDA recently approved the Acufocus Kamra Inlay in the United States. Given the number of presbyopes (including myself), this sounds like quite an exciting addition to our refractive armamentarium.

However, as a conservative corneal specialist, I feel that, like all new technology, caution is advised.

The Kamra implant is a small, thin, ring-shaped inlay measuring 3.8mm in diameter and 5 microns thick. That is one-tenth the thickness of a human hair. There is a 1.6mm aperture in the center of the Kamra Inlay which acts as a pinhole. The ring itself has approximately 8,400 microscopic holes that are each approximately 5-10 microns wide, which allow for the flow of nutrients through the cornea. Surgically, the procedure involves the creation of a femtosecond laser pocket at a depth of approximately 200 microns in the patient’s non-dominant eye. The Kamra implant is placed over the first Purkinje image. The Kamra design is such that the depth of focus in the non-dominant eye is increased through the pinhole effect, while having a relatively minimal effect on distance vision.

Worldwide (especially in Japan) there have been tens of thousands of these Kamra implants placed. In the United States, there have been a few FDA study sites, but not many lenses have been implanted.

For best results, the non-dominant eye should be between +0.50 diopters and -0.75 diopters. This can be either intrinsic ametropia, or if a patient is myopic or hyperopic, a LASIK can be performed such that the patient is brought into this range. Later, the Kamra implant is placed in a femtosecond pocket created below the LASIK flap.

In the FDA study, at 12 months, 84% of patients could see 20/40 or better uncorrected at near in the Kamra eye. Binocularly, 94% could see 20/40 or better uncorrected at near. With respect to uncorrected distance vision in the implanted eye, patients lost an average of 3 letters at 12 months. Initially, approximately 9% of patients had to have their Kamra Inlays removed over the course of the first 5 years, primarily for visual complaints or medical indications. However, since the FDA study, as surgeons have become more comfortable with the procedure, and the Kamra Inlay is placed in a deep stromal pocket vs. under a LASIK flap, the explant rate is now approximately 2%.

However, even with the deep scleral pocket technique, 4% of patients still experience aggressive wound healing characterized by stromal thickening over the inlay, central flattening, and the development of haze over the in-lay, and a hyperopic shift. Most of these patients improve with intense steroid therapy. However, a certain number of these patients will require explantation.

SO WHO IS A GOOD CANDIDATE?

Like all refractive surgery patients, the patients must have reasonable expectations and be completely informed of not only what to expect, but of all the potential risks and complications. Ideally, patients can read cell phones, tablet devices, computer, and see newsprint. However, if patients need or want to read small print for long periods of time, they still may need to use low power readers. In addition to a very detailed explanation of the realistic expectations, it would not be a good idea to implant these devices in patients who are professional drivers or pilots. Additionally, nervous and obsessive patients would not be good candidates.

Shortly, you will be hearing advertisements on the radio and seeing electronic and print media advertisements for these Kamra implants. Accordingly, patients will be asking you about them.

LOOKING FORWARD

Currently, the Kamra inlay is the only FDA approved device. However, there are a number of other inlays in the pipeline which may offer advantages over the Kamra implant. From my extensive review of the literature as well as talking to corneal specialists throughout the world, although many of these lenses offer potentially excellent results, there is certainly no “perfect” inlay available at this time. Not that perfection is necessary; however, I need to ensure that my patients and yours receive a product that has a very high success rate and a very low chance of causing either unwanted side effects or potential corneal damage. Even if “most patients” are thrilled, if 4% are unhappy, that means if you do 250 surgeries a year (conservatively) that’s at least ten unhappy patients per year. That number may seem low an absolute value, however, to me, that is an unacceptably high “failure rate” for patients expecting to get rid of reading glasses and not lose distance acuity or contrast.

OTHER IMPLANTS

The Raindrop implant is expected to be the next approved by the FDA. It is a 2mm hydrogel inlay which is 30 µm thick and creates a curvature change at the surface of the cornea. Patients gain 5 to 6 lines of visual acuity and lose approximately one line of distance visual acuity. Halos and glare do not seem to be a problem in these patients.

The FlexiVue is a 3mm hydrophilic acrylic lens with add power between 1.50 and 3.50 diopters. Although this lens significantly improves near visual acuity, it significantly diminishes distance visual acuity in the implanted eye.

As you know from working with me for many years, I do not believe in jumping onto new technology as soon as it is FDA approved. At this time, as a safety-oriented conservative cornea and refractive surgeon, I am electing not to implant the Kamra Inlay until there is more United States experience and I am convinced that they are effective and produce the kind of results that our demanding patient population expects and deserves.

As always, please call me if you have any questions.

Mark

Sarah Lee shares her successful LASIK experience. Click below to enjoy her video.

Physicians and patients have traveled from all over the world to Mark R. Mandel, MD

If you would like to meet with Dr. Mandel to discuss your personal vision needs, please contact our office today to schedule a consultation.

Click here to go to the Nordic Patient Fulfillment Site.

Practitioner’s Number: 121869


Laser Refractive Surgeries

Laser refractive surgery corrects focusing errors of the eye (e.g., nearsightedness, farsightedness, astigmatism) in order to improve visual sharpness and clarity. Procedures include LASIK, laser cataract surgery and refractive lens exchange.

Read More >>

Premium Cataract Surgery

At Optima Eye we offer premium cataract surgery. Patients can opt for laser cataract surgery and / or premium intraocular lens implants, with several options to fit your unique lifestyle.

Read More >>

Complete Eye Care

Dr. Mandel and his team of professionals offer a complete continuum of general eye care services to accommodate every patient’s needs — whether those needs are as simple as a routine eye exam, or as complex as laser vision correction.

Read More >>

Dry Eye Treatment

Dry eye syndrome, which affects more than 100 million people worldwide, can be painful and debilitating. Dr. Mandel uses several approaches to treat dry eye, ranging from medication to punctal plugs.

Read More >>


  • Navigation
  • Mark R. Mandel, MD
  • Laser Vision Correction
  • Vision Correction Options

Hayward Location

1237 B Street
Hayward, CA 94541

Santa Clara Location

3945 Freedom Circle, Suite 130
Santa Clara, CA 95054

Castro Valley Location

20400 Lake Chabot Road, Suite 302
Castro Valley, CA 94546

Concord Location

1401 Willow Pass Rd., Suite 100
Concord, CA 94520
Switch To Mobile Version
© 2017 Mark R. Mandel, MD | LASIK Web Marketing powered by Ceatus Media Group, LLC